BYHFP - DRI ALL PURPOSE LUBRICANT-AEROSOL

  • MSDS: BYHFP
  • Manufacturer: STATE CHEMICAL MFG CO
  • Product Name: DRI ALL PURPOSE LUBRICANT-AEROSOL
  • National Stock Number: 9150-00N010072
Product Identification

Product ID:DRI ALL PURPOSE LUBRICANT-AEROSOL
MSDS Date:01/01/1994
FSC:9150
NIIN:00N010072
MSDS Number: BYHFP

Responsible Party
STATE CHEMICAL MFG CO
3100 HAMILTON AVE
CLEVELAND, OH 44114-3783
US

Emergency Phone: 216-861-7114

Info Phone: 216-861-7114

Cage: 53798

Contractor
STATE CHEMICAL MANUFACTURING CO.
CLEVELAND, OH 44114-3701 US

Telephone: 216-861-7114

Cage: 53798

Ingredients

AN INCONSPICUOUS AREA BEFORE USING. WIPE OFF

RTECS: 9999999ZZ


PRECAUTIONS BEFORE USING THE PRODUCT. THESE PRODS

RTECS: 9999999ZZ


NOT FOR HOUSEHOLD USE OR RESALE. KEEP OUT OF THE

RTECS: 9999999ZZ


STODDARD SOLVENT; (MINERAL SPIRITS) MAY CONTAIN ING 2

CAS: 8052-41-3

RTECS: WJ8925000

Fraction By Weight: <20%

OSHA PEL 500 PPM

ACGIH TLV: 100 PPM


BENZENE, 1,2,4-TRIMETHYL-; (1,2,4-TRIMETHYLBENZENE) (SARA

CAS: 95-63-6

RTECS: DC3325000

Fraction By Weight: <1%

OSHA PEL 25 PPM

ACGIH TLV: 25 PPM


ETHYLENE, TETRACHLORO-; (PERCHLOROETHYLENE)

CAS: 127-18-4

RTECS: KX3850000

Fraction By Weight: <80%

OSHA PEL 100 PPM, Z-2

ACGIH TLV: 25 PPM/100 STEL, A3

EPA Report Quantity: 100 LBS

DOT Report Quantity: 100 LBS


CARBON DIOXIDE

CAS: 124-38-9

RTECS: FF6400000

Fraction By Weight: <10%

OSHA PEL 5000 PPM

ACGIH TLV: 5000 PPM/30000 STEL


BEFORE USING. WIPE OFF OVERSPRAY IMMEDIATELY.

RTECS: 9999999ZZ


WITH ORGANIC CARTRIDGES.

RTECS: 9999999ZZ


SWALLOWED. DO NOT STORE IN DIRECT

RTECS: 9999999ZZ


ARE HEAVIER THAN AIR & WILL COLLECT IN LOW AREAS SUCH

RTECS: 9999999ZZ


ELECTRONIC COMPUTERS OR ELECTRONIC MEMORY

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE:PROLONGED EXPOSURE TO VAPORS MAY
RESULT IN DIZZINESS, HEADACHE, OR NAUSEA. REPEATED CONTACT WITH
THIS PRODUCT MAY BE IRRITATING AND CAUSE ANESTHETIC EFFECTS TO THE
SKIN. CHRONIC:OVEREXPOSURE TO THIS MATERIAL (OR ITS COMPONENTS)
HAS BEEN SUGGESTED AS A CAUSE OF LIVER ABNORMALITIES, KIDNEY
DAMAGE, (EFTS OF OVEREXP)
Explanation of Carcinogenicity:TETRACHLOROETHYLENE:IARC MONO, SUPP, VOL
7, PG 355, 1987:GROUP 2B. NTP 7TH ANN RPT ON CARCINS, 1994:ANTIC TO
BE (SUPDAT)
Effects of Overexposure:HLTH HAZ:LUNG DAMAGE, BRAIN DAMAGE, AND SPLEEN
DAMAGE IN HUMANS. THE NATIONAL CANCER INSTITUTE HAS CONCLUDED FROM
THE RESULTS OF THE BIOASSAY THAT PERCHLOROETHYLENE IS A CARCIN
ACCORDING TO NTP & IARC . THIS PRODUCT CNTNS A SUBSTANCE KNOWN TO
THE STATE OF CALIFORNIA TO CAUSE CANCER.
Medical Cond Aggravated by Exposure:LIVER DISEASE AND RHYTHM DISORDERS
OF THE HEART AND RESPIRATORY DISORDERS.

First Aid

First Aid:INGEST:SEEK MED ATTN IMMED. DO NOT INDUCE VOMIT DUE TO ASPIR
HAZ. INHAL:REMOVE PERSON TO FRESH AIR. ADMIN OXYG IF AVAIL. SEEK
MED ATTN PROMPTLY. IF BRTHG HAS STOPPED, PERFORM ARTF RESP.
EYES:FLUSH IMM ED W/PLENTY OF COOL WATER FOR @ LEAST 15 MINS. IF
IRRIT PERSISTS, SEEK MED ATTN. CONT LENSES SHOULD NOT BE WORN WHEN
WORKING W/PROD. SKIN:WASH IMMED W/PLENTY OF SOAP & WATER. REMOVE
SOAKED (SUPDAT)

Fire Fighting

Flash Point Method:TCC
Flash Point:105F,41C
Extinguishing Media:WATER FOG, DRY CHEMICAL OR CARBON DIOXIDE.
Fire Fighting Procedures:NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP .
KEEP CNTNRS COOL. USE SHIELDING TO PROTECT PERSONNEL FROM VENTING,
RUPTURING OR BURSTING CANS.
Unusual Fire/Explosion Hazard:EXPOSURE TO TEMPERATURES ABOVE 120F.

Accidental Release

Spill Release Procedures:VENTILATE SPILL AREA. ABSORB SPILL ON OIL
ABSORB. PUT INTO CNTNR. DISPOSE OF AS HAZARDOUS WASTE.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:CONTENTS UNDER PRESS. DO NOT
PUNCTURE/INCIN CANS. DO NOT STORE CANS WHERE TEMP MAY EXCEED 120F.
NONFLAM. HARMFUL/FATAL IF SWALLOWED.
Other Precautions:DO NOT STORE IN DIRECT SUNLIGHT. DO NOT USE IN POORLY
VENTILATED/CONFINED SPACES. VAPS ARE HVR/AIR & WILL COLLECT IN LOW
AREAS SUCH AS PITS, DEGREASERS, STOR TANKS, & OTHER CONFINED AREAS.
DO NOT SMOK E WHILE USING. THIS PROD CNTNS (SUPDAT)

Exposure Controls

Respiratory Protection:USE NIOSH/MSHA APPRVD SCBA WHEN USING THIS PROD
IN ANY AREA W/OUT VENT/WHEN SPRAYING MORE THAN ONE-HALF CAN
CONTINUOUSLY. IN AREAS W/VAP ABOVE TLV BUT STILL PLENTY OF OXYG,
USE NIOSH/MSHA APPRVD CARTR IDGE TYPE RESP FITTED (ING 6)
Ventilation:USE VENTILATION TO KEEP VAPOR CONCENTRATION BELOW TLV.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:SOURCE OF CLEAN WATER NEARBY IN CASE OF
ACCIDENTAL EYE SPLASHING.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EXPLAN OF CARCIN:CARCIN. ANIMAL:LIVER. FIRST AID PROC:CLTHG PROMPTLY.
IF IRRIT PERSISTS, CONT PHYS. NOTE TO PHYS:DO NOT ADMIN ADRENALIN
FOLLOWING EXPOS. OTHER PREC:AFFECT PLASTICS & PAINTS. NOT FOR US E
ON ELEC COMPUTERS/ELECTRONIC MEMORY SYS. BE CAREFUL AROUND PAINTED
SURF. ALWAYS TEST AN INCONSPICUOUS AREA (ING 5)

Chemical Properties

Boiling Pt:B.P. Text:>150F,>66C
Spec Gravity:1.3 (WATER =1)
Evaporation Rate & Reference:NOT KNOWN
Solubility in Water:NIL
Appearance and Odor:CLEAR, AMBER AEROSOL SPRAY WITH A SOLVENT ODOR.
Percent Volatiles by Volume:95(WT)

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS.
Stability Condition to Avoid:EXPOSURE TO 120F.
Hazardous Decomposition Products:EXPOSURE TO EXTREME TEMPERATURES MAY
PRODUCE CARBON MONOXIDE, CARBON DIOXIDE, HYDROGEN CHLORIDE, OR
PHOSGENE GASES.

Disposal

Waste Disposal Methods:DO NOT INCIN/PUNCTURE CANS. GIVE CANS TO A DISP
SERVICE EQUIPPED TO SAFELY DISPOSE OF PRESSURIZED CNTNRS. THE USED
LIQUID IS RCRA HAZ WASTE (NO. F001). FOLLOW ALL FEDERAL, STATE AND
LOCAL REGS REGARDI NG WASTE DISPOSAL.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.